4 - CONTROL UNIT
PD12 is provided with a display that, not only makes
programming simple, but also allows a continuous monitoring of
the input statuses; in addition, thanks to a menu structure, the
working schedule and the operation logic can be set easily.
In compliance with the European standards concerning electrical
safety and electromagnetic compatibility (EN 60335-1, EN 50081-
1 and EN 50082-1) it has been equipped with the low voltage
circuit total electric insulation (motors included) from the network
voltage.
Other characteristics:
•
Power supply protected from short circuits within the
controller, on the motors and on the connected accessories.
•
Adjustment of the power by partializing the current.
•
Detecting obstacles by monitoring the current on the motors
(current sensing probe)
•
Automatic learning of the operation time
•
Obstacle sensor: a system allowing detection of whether
movement of the gate is impeded by an obstacle.
This system is based on measurement of the current absorbed
by the motor: an unexpected increase in current absorption
indicates the presence of an obstacle.
•
Tests for safety devices (photocells and safety ribbons) before
each opening.
•
Deactivation of safety inputs through the configuration
menu: no jumper is required for terminals concerning safety
devices that have not been installed, yet. You will only need
to disable this function from its relevant menu.
•
The device can operate without mains power, by using the
optional battery pack (code 161212).
•
Low voltage output that can be used for a signal light or a
24V flashing light.
•
Auxiliary relay with programmable logic for courtesy light,
flashing light or other use.
•
ENERGY SAVING function
+
4.1 - ENERGY SAVING function
BATTERY
This function is useful for reducing the energy consumption of the
automation device while in stand-by mode.
If the function is enabled, the control unit will enter ENERGY
SAVING mode under the following conditions:
•
5 seconds after completion of an operational cycle
•
5 seconds after an opening (if automatic closure is not
enabled)
•
30 seconds after exiting the programming menu
In ENERGY SAVING mode, power to the accessories, display and
flashing lights is deactivated.
ENERGY SAVING mode is exited:
•
If an operational cycle is activated
•
If one of the menus is accessed
4.2 - INSTALLATION
Installation of control unit and safety devices must be carried out
with power disconnected.
4.3 - CONNECTION OF THE MOTOR
The control unit is supplied already connected to the MASTER
motor.
The SLAVE motor (if used) should be connected to terminals
K1 - K2 - K3, following the polarity indicated on the labels
attached to the control unit and the Slave motor itself.
Max 500mA
RECEIVER
Control unit model: PD12
POWER SUPPLY
- 44 -
(SLAVE)
(MASTER)
M2
24Vdc
M1
24Vdc
24 Vdc