DESCRIPTION
Activation inputs (START and START P.)
PD12 control unit is equipped with two activation inputs, whose operation
depends on the programmed operation modes (see chapter 4.7):
Standard mode
Start inputs from terminal board are disabled.
Radio inputs operate in standard mode
Open/Close command
Manned operation
Timer mode
Stop Input
The input STOP is not available
The input STOP stops the gate: pressing the command START the gate
continues the motion
The command STOP stops the gate: at the next START the gate starts
moving in the opposite direction
Exterior photocell input
This menu makes it possible to enable the exterior photocell input, i.e.
inactive during opening (see the section regarding installation).
Input enabled even at standstill gate too: the opening movement does not
start if photocell is interrupted
Input disabled (ignored by the control unit)
Input enabled for the closing phase only.
Warning: if you select this option, you must disable photocell test
Interior photocell input
This menu makes it possible to enable the interior photocell input, i.e.
active during opening and closing (see the section regarding installation).
Input disabled (ignored by the control unit)
Input enabled
Test of the photocells
In order to achieve a safer operation for the user, the unit performs a
photocells operational test, before a normal working cycle.
If no operational faults are found, the gate starts moving.
Otherwise, it will stand still and the flashing light will stay onfor 5 sec.
The whole test cycle lasts less than one second.
Safety ribbon 1 input
This menu allows enabling the input for type 1 safety ribbon (fixed
ribbons)
Input disabled (ignored by the control unit)
Input enabled during the opening and disabled during the closure
Input enabled in opening and closure
Safety ribbon 2 input
This menu allows enabling the input for type 2 safety ribbon, that is to say
mobile ribbons
Input disabled (ignored by the control unit)
Input enabled during closure and disabled during opening
Input enabled in opening and closure