5.5 Installing the operator
The following illustrations are only examples, given that the space available for anchoring the operator and accessories may
vary from gate to gate. It is up to the installer, thus, to choose the most suitable
Lay the corrugated tubing needed for the connections deriving from the junction box.
N.B. the number of tubes depends on the type of system and accessories employed.
Warning: after establishing the best point to which you will secure the gate bracket, secure the bracket to the pillar and make sure
the quotas shown in the table below are met.
Note: by increasing measure B, the opening angle and gate speed are reduced, while the gearmotor thrust is increased. By increasing
the measure A, the opening angle and gate speed are increases, while the gearmotor thrust is decreased.
Pillar bracket
Ideal securing
Gate bracket
point
solution.
Electric cable junction box
Opening
90°
120°
A
B
C
(mm)
(mm)
(mm)
130
130
60
130
110
50