Kohler K-728 Guia De Instalacion página 5

Ocultar thumbs Ver también para K-728:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

E-Ring
Missing Tooth
Plaster Guard
Mixed water supply 3/4"
copper tubing or piping
4. Two-Way Valve Installation
Convert to a Two-Way Valve
IMPORTANT! If less than three accessories will be installed, do not
plug any outlets on this transfer valve without completing the
two-way conversion. The transfer valve is not intended to be used
as a shut-off valve without the two-way conversion.
Temporarily remove the plaster guard.
Rotate the detent until positioned vertically; see above
illustration.
Verify the missing tooth is oriented up.
Identify the plug at the center of the valve body and the spacer
underneath the detent.
Using a hex wrench, remove the plug. Discard the plug.
Plug the port that will not be used (either the left or right port)
with a 1/2" NPT plug.
Use pliers to remove the spacer from beneath the detent.
Push the detent down; ensure the points of the detent engage the
notches of the valve cartridge.
Install the spacer above the detent and under the E-ring.
Install the Two-Way Valve
Install 1/2" copper tubing or 1/2" piping for both accessories.
Securely fasten the piping and outlet ells to the framing.
Kohler Co.
Accessory # 2
Water Line
Detent
Spacer
5
Accessory # 1
Water Line
Plug
1/2"
NPT Plug
1145567-2-B

Publicidad

Tabla de contenido