Connect Electrical Supply

Refer to data plate for more information. See "Service"
for data plate location.
The branch-circuit breakers ampacity, the wire sizes and
the connections must be conform to the requirements of
the National Electrical Code or Canadian Electrical
Code and all local codes and ordinances.
Attach flexible conduit to the junction box. Connect the
lead wires to the junction box supply wires in proper
phase:
black (L1) to black
red (L2) to red
green to ground
The mains connecting cable must at least correspond to
the type SJTO 3x16 AWG 105°C. The mains connecting
cable must only be purchased through and connected
by an authorised specialist.
Connection with a plug
Plug has to be conform with NEMA
CONFIGURATIONS FOR PLUGS AND
RECEPTACLES.
The appliance must be properly grounded.
Plug must be rated not less than type 6-20 P (2-pole
3-wire grounding).
Only a qualified electrician should connect the
plug.
Install a socket outlet earthed in accordance with
regulations approx. 27" (700 mm) above the floor
behind the appliance. The socket outlet must still
be accessible after installation.

Check the Installation

9
WARNING
Before you plug in an electrical cord or turn on
power supply, make sure all controls are in the
OFF position.
Remove everything from the cooktop surface. Clean
cooktop surface with cooktop cleaning creme.
Switch on the circuit breaker.
Verify that elements function properly.

Drain installation

The device is intended to be permanently connected to
the water outlet, but can also be installed without a
permanent connection using special accessory
AG 060 000.
Note: Keep the bottom drain valve in the lower cabinet
accessible.
Possibilities for drain installation:
Sewage connection present in lower cabinet:
Fixed connection without free falling distance
according to DIN 1986 Part 1. A check valve must
be installed.
Recommendation: AG 050 000 Drain installation
set (available separately as a special accessory).
Sewage connection present in lower cabinet:
Fixed connection with free falling distance
according to DIN 1986 Part 1. A check valve should
be installed.
Recommendation: AG 050 000 Drain installation
set (available separately as a special accessory).
No fixed connection present in lower cabinet:
Drain in water-collecting container (e.g. bucket).
Only possible with AG 060 000 Drain installation
set (available separately as a special accessory).