6.2 - CPI SWITCH INSTALLATION and CALIBRATION
It is necessary to close the gas prior to installation.
NOTE: CPI connector wiring (21) needs to be carried out taking
care to ensure the product's IP65 rating.
• Unscrew the cap (24) under the valve body (4);
• In place of the cap (24) screw in the CPI kit (23). Make
sure that between the body (4) and CPI kit (23) there is
the aluminium washer (18);
• Tighten the CPI kit (23) to the valve's body (4) with a special
commercial spanner;
• Before wiring the CPI connector (21), unscrew and remove
the central screw (20);
• Connect the CPI connector (21) terminals 1 and 2 in series
to the signalling device. Use the special cable terminals (see
the figures in 3.2);
• Wire the CPI connector (21) with a 2x1mm² cable having an
external Ø of 6.7 mm. The cable must have double sheathing,
be suitable for use outdoors, with minimum voltage of 500V,
and minimum temperature of 90°C;
• Secure the CPI connector (21), tightening (recommended
tightening torque 0.4 N.m ± 10%) the centre screw (20);
• To calibrate the microswitch, loosen the fastening nut (22)
and position (by screwing on or off) the adjustment ring nut
(19) so that, with the solenoid valve in a closed position,
the microswitch provides the signal;
• Secure the adjustment ring nut (19) in that position by
tightening the nut (22);
• The kit is now installed. Open and close the solenoid valve
(by supplying and cutting off power) 2-3 times to make sure
the microswitch is signalling correctly.

9.0 - RATING PLATE DATA

The rating plate data (see example provided here) includes the following:
• Manufacturer's name/logo and address (possible distributor name/logo)
• Mod.:
= device name/model followed
• CE-51CN4180
= certification pin number
• Cl. A
= Seal strength in counterflow at 150 mbar in accordance with EN 161
• Gr. 2
= Mechanical resistance group 2 in accordance with EN 161
• EN 161
= Product reference regulation
• P. max
= Maximum pressure at which product operation is guaranteed
• PS
= Allowable maximum pressure
• IP....
= Protection rating
• 230V....
= Power supply voltage, frequency (if Vac), followed by electrical absorption
Example of electrical absorption indications: 89/25 VA indicates 89 VA on PTO, 25 VA at full speed
• TS
= Temperature range within which product operation is guaranteed
= Conformity with Regulation (EU) 2016/426 followed by Notified Body No.
(if it is present) = Conformity with PED Dir. followed by Notified Body No.
• year
= Year of manufacture
• Lot
= Product serial number (see explanation below)
• U1804
= Lot issued in year 2018 in the 4th week
• 2185
= progressive job order number for the indicated year
• 00001
= progressive number referring to the quantity of the lot
EV(Q-R-S-T)-1-3-6
by the connection diameter

7.0 - TRANSPORT, STORAGE AND DISPOSAL

• During transport the material needs to be handled with care,
avoiding any impact or vibrations to the device;
• If the product has any surface treatments (ex. painting,
cataphoresis, etc) it must not be damaged during transport;
• The transport and storage temperatures must observe the
values provided on the rating plate;
• If the device is not installed immediately after delivery it must be
correctly placed in storage in a dry and clean place;
• In humid facilities, it is necessary to use driers or heating
to avoid condensation;
• At the end of its service life, the product is to be disposed of
in compliance with the legislation in force in the country where
this operation is performed.
8.0 - WARRANTY
The warranty conditions agreed with the manufacturer at the
time of the supply apply.
For damage caused by:
• Improper use of the device;
• Failure to observe the requirements described herein;
• Failure to observe the regulations pertaining to
installation;
• Tampering, modification and use of non-original spare parts;
are not covered by the rights of the warranty or compensation for
damage.
The warranty also excludes maintenance work, other
manufacturers's assembling units, making changes to the
device and natural wear.
Mod: EVS-1 DN 50
CE- 51CN4180 CI.A GR.2 EN 161
IP65 – 230 V/50-60 Hz 89/25 VA
year: 2018
14
Madas Technical Manual - 1|1.5b - REV. 0 of 10
P.max=PS= 1 bar
TS: -20+60 °C
0051
0497
Lot: U1804 2185/00001
May 2018