Instructions For Connection To Power Supply & Elect. Ground 230V - Clarke Alto C2K-1600HD Libro De Instrucciones

Tabla de contenido

Publicidad

230V
Grounded
Outlet
Grounding Pin
(United States, Mexico and Canada)
Figure 4
230V
Toma corriente
con polo de tierra
Terminal
de tierra
Figure 4a
230V
Prise de
courant avec
mise à la terre
Broche de mise à
la terre.
Figure 4b
Page -18 -
Grounded
Outlet
Box
Tapa del toma
corriente con
polo de tierra.
Boîte de sortie mise à
la terre
CLARKE TECHNOLOGY Operator's Manual - C2K-1600HD, 1800HD and 2000HD Polisher
230V MACHINES
Instructions for connection to the power
supply and the electrical ground.
This product must be grounded. If it should malfunction
or breakdown, grounding provides a path of least
resistance for electric current to reduce the risk of
electrical shock. This product is equipped with a cord
having an equipment-grounding conductor and ground-
ing plug. The plug must be inserted into an appropriate
oulet that is properly installed and grounded in accor-
dance with all local codes and ordinances.
WARNING: Improper connection of the equip-
ment-grounding conductor can result in a risk of
electric shock. Check with a qualified electrician
or service person if you are in doubt as to whether
the outlet is properly grounded. Do not modify the
plug provided with the product - if it will not fit the
outlet, have a proper outlet installed by a qualified
electrician.
This product is for use on a nominal 230V circuit and
has a grounding attachment plug that looks like the plug
illustrated in Fig. 4. Make sure that the product is
connected to an outlet having the same configuration
as the plug. No adaptor should be used with this
product.
WARNING: To prevent possible electric shock,
protect the machine from rain. Keep the machine
in a dry building.
WARNING: To prevent possible electric shock,
always use a 3-wire electrical system connected
to the electrical ground. For maximum protection
against electrical shock, use a circuit that is
protected by a ground fault circuit interrupter.
Consult your electrical contractor.
WARNING: Do not cut, remove or break the
ground pin. If the outlet does not fit the plug,
consult your electrical contractor.
WARNING: Have worn, cut or damaged
cords replaced by an authorized service person.
EXTENSION CORDS
Use only an approved extension cord with three
conductors, a plug with three terminals, and a
connector body with three holes. The machine has a
power cord with wire size 14 AWG (AWG means
American Wire Gauge).
WARNING: If you use an extension cord,
use an extension cord with minimum wire size
12 AWG. Do not use an extension cord longer
than 50 feet. Do not join two extension cords.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Alto c2k-1800hdAlto c2k-2000hd

Tabla de contenido