V2 TORQ-D Serie Manual De Instrucciones página 50

Motor electromecanico irreversibles 24v para puertas correderas hasta 500 kg de peso
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 82
PARAMETER
VALUE
CoS1
no
APCh
AP
CoS2
no
APCh
Ch
Co.tE
no
rESi
Foto
S.EnC
0 - 7
i.Adi
no
Si
FinE
no
Si
DESCRIPTION
Safety ribbon 1 input
This menu allows enabling the input for type 1 safety ribbon, that is to say,
fixed ribbons
Input disabled (ignored by the control unit)
Input enabled in opening and closure
Input enabled during the opening and disabled during the closure
Safety ribbon 2 input
This menu allows enabling the input for type 2 safety ribbon, that is to say
mobile ribbons
Input disabled (ignored by the control unit)
Input enabled in opening and closure
Input enabled during closure and disabled during opening
Test of the safety edges
This menu allows setting the method of control of the safety edges
working
Test disabled
Test enabled for conductive rubber safety edges
Test enabled for optical safety edges
Encoder sensitivity
This menu allows the sensitivity of the rate sensor to be adjusted.
A decreased rate below the set threshold indicates the presence of an
obstacle.
0
If set to
the obstacle is only detected when the gate is stopped.
When the sensor intervenes, the gate stops and is operated in the reverse
direction for 3 seconds to remove the obstacle.
The next start command restarts the movement in the previous direction.
Enabling the ADI device
This menu makes it possible to enable operation of the device connected
to the ADI connector.
Si
PLEASE NOTE: selecting
and pressing MENU accesses the
configuration menu for the device connected to the ADI connector.
This menu is managed by the device itself and is different for each
device. Please refer to the manual for the device.
Si
If the
option is selected, but no device is connected, the display will
show a series of dotted lines.
Exiting the ADI device configuration menu returns to the
Interface disabled, any signals will be ignored
Interface enabled
End of Programming
This menu allows to finish the programming (both default and
personalized) saving the modified data into memory
Do not exit the programming menu
Exit from the programming menu, storing the parameters set
i.Adi
- 48 -
DEFAULT
MEMO
no
no
no
0
no
option
no

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Torq500d-24vTorq400d-24v-f

Tabla de contenido