Motor Overriding System; Installation Layout - V2 FORTECO 2500-I Manual De Instrucciones

Ocultar thumbs Ver también para FORTECO 2500-I:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3.5 - MOTOR OVERRIDING SYSTEM

In case of absence of current, the gate can be released by
operating on the motor:
1. Open the hatch of the lock J in front of the motor
2. Insert the key K in the lock and turn clockwise to open
the hatch of the release on the side
3. Insert the key L into the hole and turn clockwise until
reached the limit switch
4. At this point you can manually move the gate
To restore the automation, proceed as follows:
1. Bring the gate to the fully closed position
2. turn the key L anticlockwise until reached the limit
switch, then draw it out
3. turn the key K anticlockwise closing the hatch of the
lock, then draw it out
4. Close the lock with the hatch J

3.6 - INSTALLATION LAYOUT

COMPONENTS
Motor
1
2
Transmitter
Receiving module
3
Photocells
4
Flashing light
5
LENGTH OF THE CABLE
Power supply 230V
Photocells (TX)
Key switch
Photocells (RX)
Flashing light
Antenna (integrated into the flashing light)
L
5
1
3
E
C
ADDITIONAL ACCESSORIES
Key switch
A
B
Pillar photocells
Pillar-mounted digital radio switch
C
Safety edges
D
WES-ADI module (via radio management of edges)
E
WES sensors
F
< 10 metres
3G x 1,5 mm
2
2 x 0,5 mm
2
4 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1,5 mm
2
RG174
- 35 -
K J
4
D
F
2
from 10 to 20 metres
3G x 1,5 mm
2
2 x 0,5 mm
2
4 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1,5 mm
2
RG174
A
B
from 20 to 30 metres
3G x 2,5 mm
2
2 x 0,5 mm
2
4 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1,5 mm
2
RG174

Publicidad

Tabla de contenido
loading

Tabla de contenido