15 - TESTING AND START-UP

In implementing the automation device, these are the most
important steps for guaranteeing maximum safety.
V2 recommends the application of the following technical
standards:
• EN 12445 (Safety in the use of automated closures, test
methods)
• EN 12453 (Safety in the use of automated closures,
requirements)
• EN 60204–1 (Safety of Machinery, electrical equipment of
machines, part 1: general principles)
In particular, with reference to the table in the section
"PRELIMINARY CHECKS and IDENTIFICATION OF THE TYPE OF
USE" in the majority of cases, it will be necessary to measure the
impact force, in accordance with the provisions of EN 12445.
Adjusting the operating force is possible by programming the
electronic circuit board, and the impact force profile should be
measured using an appropriate device (itself also certified and
subjected to annual calibration) capable of tracing the force-time
graph.
The result should be in compliance with the following maximum
values:
Force
1400 N
L > 500 mm
400 N
L = 50 ÷ 500 mm
150 N
25 N
0.75 s
For a comprehensive guide on the installation of automation
devices and the documentation to be prepared, we recommend
use of the guides issued by the Italian association UNAC,
obtainable from www.v2home.com
Dynamic
IMPACT force
Static CRUSHING
force
5 s

16 - MAINTENANCE

Maintenance should be performed in full compliance with
the safety instructions described in this manual and in
accordance with current legal and regulatory provisions.
The recommended interval between each maintenance
operation is six months, the checks involved should at least
relate to:
• the perfect efficiency of all warning devices
• the perfect efficiency of all safety devices
• measurement of the gate operating forces
• the lubrication of mechanical parts on the automation
device (where necessary)
• the state of wear of the mechanical parts on the
automation device
• the state of wear of the electrical cables on the
electromechanical actuators
The result of each check should be recorded in a gate
maintenance log.
17 - DISPOSAL OF THE
PRODUCT
As for the installation operations, even at the end of this
product's life span, the dismantling operations must be
carried out by qualified experts.
This product is made up of various types of materials:
some can be recycled while others need to be disposed of.
Find out about the recycling or disposal systems envisaged
by your local regulations for this product category.
Important! – Parts of the product could contain
pollutants or hazardous substances which, if released
into the environment, could cause harmful effects to the
environment itself as well as to human health.
As indicated by the symbol opposite, throwing away this
product as domestic waste is strictly forbidden. So dispose
of it as differentiated waste, in accordance with your local
Time
regulations, or return the product to the retailer when you
purchase a new equivalent product.
Important! – the local applicable regulations may
envisage heavy sanctions in the event of illegal disposal of
this product.
- 50 -