USE OF THE CHARGER
Charger with discharge function for 1-4 NiCD/NiMH batteries of the sizes Micro (AAA); Mignon (AA); Baby (C); Mono
(D) and 1-2 9V block.
ATTENTION
• Use only with NiCD/NiMH cells. Non rechargeable batteries or other types could cause an explosion!
• Do not attempt to charge Alkaline batteries or other types of primary batteries
• Do not dispose of batteries in fire as the battery may explode, leak or catch fire
FEATURES
Separate charging processes for each inserted cell; Automatic start of charging at contact with the cell; NiCD as well as
NIMH cells can be charged at the same time; Microprocessor controlled charging for cylindrical cells; Automatic switch-
over to trickle charging for cylindrical cells; Discharging option for cylindrical cells; Faulty cell detection for cylindrical
cells
DISPLAY FOR CYLINDRICAL CELLS (1):
Green LED blinking (1 x sec): charging
Green LED flashing: ready /trickle charge
Green LED blinking fast (2 x sec): faulty cell
Green LED´s blinking alternative from the right side to the left side: discharging
DISPLAY FOR 9V BLOCK (2):
LED flashing red: charging
DISCHARGE BUTTON (4):
Press this button (PRESS) for approx. 3 seconds to start the discharge function for the cylindrical cells.
SAFETY INSTRUCTIONS:
Keep the charger in a dry place (indoor or in-vehicle use only); In order to avoid the risk of fire and / or electrical
shock, the charger must be protected against high humidity and water; Ensure that the ventilation slots are kept free, to
guarantee perfect function of the unit and avoid over-heating; Do not plug in the charger if there are any signs of damage
to the housing, cables or plugs; Do not open or reconstruct the charger or any adaptors; In the case of a defect, please
return to an authorized service centre; Keep out of reach of children; Disconnect the device from the mains after use; To
clean the device please disconnect from the mains and use only a dry cloth