60
OUTPUT INDICATOR (GREEN)
The AC output indicator lights up when the motor starts and produces power.
DC PROTECTOR
The DC protector is automatically set to "OFF" when the electrical device connected to the
generator is running and the current is above the nominal flow rates. To reuse this device, turn
on the DC protector by pressing the "ON" button.
1.
"ON": Direct current is emitted.
2.
"OFF": No direct current is emitted.
ATTENTION: Reduce the load on the connected electrical device below the specified nominal
output of the generator if the DC protector is turned off. If the DC protector is turned off again,
stop using the device immediately and consult the Official Technical Service.
ECONOMIC CONTROL SWITCH (ECS)
"ON" ( I ): When the ESC switch is set to "ON", the economy control unit controls the engine speed according to the
load connected. The result is better fuel consumption and less noise.
"OFF" (O): When the ECS switch is set to "OFF", the motor runs at nominal speed (3200r/min), regardless of whether
a load is connected or not.
NOTE: The ECS should be set to "OFF" when using electrical devices that require a high starting
current, such as a submersible pump compressor.
EARTH CONNECTION
The ground terminal connects the ground line to prevent electric shock. When the electrical device is grounded, the
generator must always be grounded.
ON
OFF
DC PROTECTOR