Save the NG orifices in case there is a later need to restore
the appliance to use natural gas.
3.Identify the correct placement of the LP gas orifices as
laid out on the orifice package card.
HGI8054
CTR/CENTRE
1.22
LR
ARRIÈRE
GAUCHE
0.70
LF
AVANT GAUCHE
0.86
FRONT/ AVANT /FRENTE
HDI8054C/HDI8054U
MIDDLE/CTR/CENTRE 1.09
LR
ARRIÈRE
GAUCHE
TRASERO IZQUIERDO
0.70
LF
AVANT GAUCHE
FRENTE IZQUIERDO
0.86
FRONT/AVANT/FRENTE
Note: The orifice sizes are engraved on the top of each
orifice. It is very important to install the correct orifice size
for each burner.
9001080874 Rev A
All manuals and user guides at all-guides.com
HGIP054
CTR/CENTRE
1.22 AND 0.44
LR
ARRIÈRE DROIT
0.70
LF
AVANT DROIT
1.14
HDIP054C/HDIP054U
MIDDLE/CTR/CENTRE 1.22
OFFSET/DECALE/ORFICIO EXCENTRICO 0.44
RR
ARRIÈRE DROIT
TRASERO DERECHO
0.70
RF
AVANT DROIT
FRENTE DERECHO
1.14
Note: The central burner has an extra hidden orifice under-
neath the center unit cap. It is necessary to remove the
burner cover plate to change the hidden (smaller) center
orifice.
smaller
center
orifice
Note: The orifice sizes are engraved on the top of each
orifice. It is very important to install the correct orifice size
for each burner.
4. Assemble LP cooktop orifices.
Place in cooktop exactly as specified on the orifice
card. Placement can be determined by matching the
orifice size to the number on the card.
5. Place the new orifice into the socket then insert each
orifice into its respective threaded hole in the jet
holder.Tighten until the orifice stops turning. DO NOT
OVERTIGHTEN!
6. Remove screws placed in jet holder to replace burner
base, burner cap and burner grate. Reinstall screws.
Note: Each burner cap must be properly positioned on the
burner base for the burner to light.
Correct Burner Cap
Placement
7. Retain natural gas orifices for future conversion back to
natural gas.
Incorrect Burner Cap
Placement
Burner Cap Placement
English 5