Parts Replacement/Maintenance
Chart 1 – Air Caps
ORDER NO. FOR
NUMBER
AIR CAP
ON CAP
704200 (High Efficiency)
TE25
704206 (HVLP)
HV30
NOTE 1: Guns with HVLP caps must not exceed 0.7 bar (10 psi) air cap pressure
with gun fully triggered. (Aproximately 24 psi gun inlet pressure.) (See
accessories for air cap test kit which is available to set the exact cap
pressure.)
NOTE 2: When removing air cap from retaining ring, don't remove slip ring (2)
or retaining ring seal (5) from retaining ring. Damage to the parts may
occur. Slip ring and retaining ring seal are not available as replacements.
Simply wipe parts clean and reassemble with new or clean air cap.
Chart 2 – Fluid Nozzles & Fluid Needles
ORDER NO. FOR
NO. ON
FLUID NOZZLE
FLUID NOZZLE
703521
PRO-200-12
703522
PRO-200-13
703523
PRO-200-14
703589
PRO-200-15
NOTE:
When replacing the fluid nozzle or fluid needle, replace both at the same
time. Lightly lubricate the threads of the fluid nozzle before reassembling.
Torque to 18–20 Nm (13–15 ft-lbs). Don't over tighten the fluid nozzle. Use
10 mm wrench supplied with gun.
RECOMMENDED
AIR FLOW
INLET PRESSURE
LPM/SCFM
BAR/PSI
1.5 – 2.0 bar
311 – 368 LPM
22 – 29 psi
11 – 13 SCFM
1.4 – 1.6 bar
368 – 424 LPM
20 – 24 psi
13 – 15 SCFM
TIP SIZE I.D.
NO. ON
(MM)
FLUID NEEDLE
1.2
PRO-301
1.3
PRO-301
1.4
PRO-301
1.5
PRO-301
ORDER NO. FOR
FLUID NEEDLE
703531
703531
703531
703531
TB-1026-D
11