5 Installation
Class 20~35:
a
117
d
a
e
48
170
Class 50~71:
a
122
d
a
e
56.5
170
a
Recommended mounting plate fixing spots
b
Pocket for the pipe port cover
c
Tabs for placing a spirit level
d
Through-the-wall hole Ø65 mm
e
Drain hose position
f
Position for the tape measure at symbol " "
g
Gas pipe end
h
Liquid pipe end
5.2.2
To drill a wall hole
CAUTION
For walls containing a metal frame or a metal board, use a
wall embedded pipe and wall cover in the feed-through
hole to prevent possible heat, electrical shock, or fire.
NOTICE
Be sure to seal the gaps around the pipes with sealing
material (field supply), in order to prevent water leakage.
1 Bore a 65 mm large feed-through hole in the wall with a
downward slope towards the outside.
2 Insert a wall embedded pipe into the hole.
3 Insert a wall cover into the wall pipe.
Installation manual
10
b
c
a
c
213
h
g
a
50
337
770
b
c
PIPING HOLE
PIPING HOLE
CENTER:170mm
CENTER:170mm
TO THE LEFT
TO THE LEFT
475
a
116.5
237
d
f
A
A
a
a
170
48
337
a
c
h
g
f
60
404
990
a b
c
a
Wall embedded pipe
b
Putty
c
Wall hole cover
Note: After completing wiring, refrigerant piping and drain piping, do
NOT forget to seal the gap with putty.
5.2.3
To remove the pipe port cover
To connect the piping on right-side, right-bottom, left-side or left-
bottom, the pipe port cover MUST be removed.
1 Cut off the pipe port cover from inside the front grille using a
coping saw.
e
(mm)
a
121.5
PIPING HOLE
PIPING HOLE
CENTER:170mm
CENTER:170mm
TO THE LEFT
TO THE LEFT
d
e
A
A
a
170
56.5
(mm)
(A)(F)TXP20~71L2V1B + FTXF20~71A2V1B
Daikin room air conditioner
3P512025-1C – 2018.01