2 independent gas line. Each line is composed of:
o
1 inlet fitting
o
1 solenoid valve
o
1 mass flow meter (0 to 50 l/min)
o
1 gas flow adjustment knurled screw
o
1 outlet shut-off fitting
-
Rotation : welding machine control
o
Single connector 32 contacts bayonet (quarter turn)
o
Velocity can be pulsed and synchronized on current pulses
o
AXXAIR machines control: SATF, SATO, SATP and SX
o
Competitor machines control: AMI, Polysoude MW (with active buttons and LED) and more in
the futur
o
Automatic calibration for machines with tachometer and adjustable resistance.
o
Closed loop control for precise velocity
o
Displaying of measured velocity and alarm in case of drift
o
Temperature protection of SATF and SATO with temperature sensor of 70°C.
o
Control of SATF/SATO with integrated buttons : START, STOP, left rotation, right rotation
o
On SATF : green LED active in cycle
-
Wire : control of wire feeder
o
Connector 10 contacts bayonet (quarter turn)
o
Velocity can be pulsed and synchronized on current pulses
o
Possibility to program a delay wire start, delay wire stop and a wire retract at the end of
welding.
-
AVC-OSC : control of AVC axis (Arc voltage control) and OSC axis (oscillation)
o
Single connector 26 contacts bayonet (quarter turn)
o
AVC pilots arc length in function of the arc voltage. Thus, the arc length is kept constant
during the cycle even if the tube is deformed.
o
OSC moves the electrode in the tube axis.
-
Auxiliary connector:
o
Possibility to start welding via an oxygen meter (dry contact).
o
Manual torch: command trigger connection (start and stop functions only).
-
Cooling system
o Max. pressure : 5 bars
o Cooling power according to norm CEI60974-2: 1,4 kW.
o Liquid fittings : Female shut-off fitting of serie 21
o Coolant : Do not use water but only AXXAIR coolant
o Tank capacity : 3 liters maximum
o Maximum flow : 2,2 liters/minute
o Flow security : < 0,5 l/min
-
Wifi: remote control of the touch screen with a smartphone or a tablet via app « Proface remote HMI ».
o Range: 20 to 30m but obstacles can highly reduce this value. Presence of other wifi network
can also highly reduce this value or even make it impossible to use.
Join
experience
Displayed flow is adapted in function of selected gas in order to have a precise value
in all cases.
Measure accuracy :
N2 and Ar : +/- 1,5 l/min
He and mixed gas: +/-2l/min up to 20l/min and +/-10% above.
SAS au capital de 135 720 € - RCS Romans B414 581 363 – Code APE 2841 Z – Siret 414 581 363 00028 – TVA FR13414 581 363
/
0,5 liters minimum
330B Route de Portes Les Valence - ZI Les Bosses - 26800 Etoile sur Rhône
Tél: +33 475 575 070 - Fax: +33 475 575 080 - commerce@axxair.com - www.axxair.com
- 48 -