Replacing the Halogen Lamps
Turn off the hood insert and allow the halogen lamp to cool.
To avoid damage or decreasing the life of the new bulb, do
not touch bulb with bare fingers. Replace bulb, using tissue or
wearing cotton gloves to handle bulb.
If new lamps do not operate, make sure the lamps are in-
serted correctly before calling service.
1.
Disconnect power.
2.
Push up on the lens and turn
it counterclockwise.
3.
Remove the bulb and replace
it with a 120-volt, 50-watt
maximum halogen bulb with a
GU10 base. Turn it clockwise
to lock it into place.
4.
Repeat steps 2-3 for the other
bulb if needed.
5.
Reconnect power.
Available Accesories
Charcoal Filter
If the model is not vented to the outside, the air will be recir-
culated through disposable charcoal filters that help remove
smoke and odors.
The charcoal filters cannot be cleaned.
They must be replaced.
Cover the grill that protects the suction motor with the carbon
filter so that the slots on the filter correspond to the pins on
the sides of the motor protection grill.
Turn the carbon filter clockwise to block them (bayonet fixing).
The charcoal filters should be replaced every 4-6 months
(depending on hood usage).
NOTE: DO NOT rinse, or put charcoal filters in an automatic
dishwasher.
NOTE: Charcoal filters are not included with the hood.
They must be ordered from your supplier.
Order the needed kit specifying your hood model and width
size.
Air deflector installation (Recirculating version)
1.
Assemble the air deflector with the duct cover bracket
with 2 - assembly screws provided.
B
A. Vent cover bracket
B. 2.9 x 6.5 mm screws
C. Deflector
2.
Measure from the bottom of the air deflector to the
bottom of the hood outlet.
B
D
E
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
3.
Cut the duct to the measured size (X).
4.
Remove the air deflector.
5.
Slide the duct onto the bottom of the air deflector.
6.
Place the assembled air deflector and duct over the
exhaust outlet from the hood.
7.
Reassemble the air deflector to the duct cover bracket
with 2 assembly screws.
8.
Seal connections with vent clamps.
1
A
B
C
A
C
X