Parameter name - ERC 214
Display at defrost
Air=actual air temperature, FrE=freezed
temperature, -d-="-d-" is displayed
Polarity
DI1 input polarity
nc=normally closed,
no=normally open
DI2 input polarity
nc=normally closed,
no=normally open
Invert alarm relay
0=normal, 1=invert relay action
Keyboard lock enable
Readouts
Controller status
S0=cooling ON/Heating ON,
S2=wait for compressor ON time to elapse,
S3=wait for compressor OFF time to elapse-
restart time, S4=drip OFF delay after defrost,
S10=cooling stop S11=cooling stopped by
thermostat/heating OFF, S14=defrosting state,
S15=fan delay state after defrost, S17=door
open (DI input), S20=emergency cooling,
S25=manual control of outputs, S30=continous
cycle/Pull-down, S32=delay of outputs at
power up
Note: hidden parameters are greyed out
DKRCE.PI.RL0.H7.ML
Code
Min
Max
Unit
o91
Air
-d-
P--
P73
nc
no
P74
nc
no
P75
0
1
P76
no
yES
u--
u00
S0
S32
Installation Guide | ERC 214
App. 0
App. 1 App. 2 App. 3 App. 4 App. 5 App. 6
(Def.)
-d-
-d-
-d-
-d-
no
no
no
no
no
no
no
no
0
0
0
0
no
no
no
no
--
-d-
-d-
-d-
no
no
no
no
no
no
0
0
-
no
no
-
| 19