Samsung NX58K7850S Serie Manual De Instalación página 20

Estufa de gas
Ocultar thumbs Ver también para NX58K7850S Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation instructions
Flexible connector hookup
Installer: Inform the consumer of the location of the gas shut-off valve.
Gas Shut-Off Valve
0.5-in or 0.75-in Gas Pipe
Tubing Line to
Oven Burner
Adapter
Control Valve
Tubing Line to
Cooktop Control
Flex
Manifold
Connector
(6-ft max.)
Pressure
Regulator
Adapter
20 English
NOTE
If your area requires a rigid pipe hookup,
contact a qualified installer, service agency,
or gas supplier.
NOTE
The gas shut-off valve should be installed
in an accessible location in the gas piping,
external to the appliance, for the purpose
of turning on or shutting off the gas to the
appliance.
Step 3. Convert to lp gas (optional)
All new gas ranges are shipped from the factory set up to use natural gas. Any
Samsung gas range can be converted to use LP gas. Refer to page 78 in the User
Manual to contact a qualified service technician.
The conversion process should only be performed by a qualified LP gas installer.
Conversion instructions and LP orifices will be supplied with the LP conversion kit.
The conversion to LP requires all burner orifices to be changed (5 surface burners
and 2 oven burners).
In addition, the nozzle on the gas pressure regulator needs to be reversed. All
replaced orifices must be left with the consumer, including the instructions and
retrofit sizes and orifice indication.
BURNER ORIFICE SIZES AND OUTPUT RATINGS (LP Gas [Propane] 10 in WCP)
Burner Location
RF
LF
RR
LR
CTR
BAKE
BROIL
BURNER ORIFICE SIZES AND OUTPUT RATINGS (Natural Gas 5 in WCP)
Burner Location
RF
LF
RR
LR
CTR
BAKE
BROIL
BTU Rate
Orifice Size [mm]
14,500
1.12
11,500
1.04
4,000
0.62
7,500
0.83
7,500
0.83
15,000
1.15
14,500
1.12
BTU Rate
Orifice Size [mm]
18,000
1.92
15,000
1.78
5,000
1.01
9,500
1.40
9,500
1.38
18,000
1.90
13,500
1.64

Publicidad

Tabla de contenido
loading

Tabla de contenido