Installation instructions
Locking screw
Locking
screw
26 English
The shutters are located at the base of the
burner manifolds near the back oven wall.
To adjust the shutter, loosen the locking
screw and rotate the shutter towards the
open or closed position as needed. If flames
are lifting off the burner ports, gradually
reduce the air shutter opening until the
flames are stabilized.
If flames are too yellow and/or too large,
gradually increase the air shutter opening
until the flames have approximately a 1-in
blue cone.
NOTE
If the range is set up for natural gas, the
flames should burn with no yellow tipping.
If the range is set up for LP gas, small
yellow tips at the end of the cones are
normal.
After the flames are adjusted properly, shut
off the oven, retighten the locking screws,
replace the oven bottom and racks, and
close the oven door.
To adjust flame low setting
Identify which burner is exhibiting too high or too low of simmer rate via manifold
panel graphics.
Simmer Set Screw
WARNING
1.
Do not completely remove the valve set screw from the valve stem. The valve
set screw is an integral part of the gas valve assembly. Removing the valve
set screw will cause gas to leak.
2.
After adjusting the valve set screw, inspect the assembly for gas leaks.
1.
Rotate a knob to "LO" position and
remove the knob from the valve shaft
while the flame is lit.
2.
Carefully push the screw driver into
the C chanel of the valve, until it hits
the simmer set screw. Make sure the
screwdriver flathead is seated into the
set screw groove.
3.
Rotate valve set screw clockwise to
decrease "LO" setting flame output, or
rotate set screw counter clockwise to
increase "LO" setting flame output.