Installation instructions
Step 3. Convert to LP gas (optional)
All new gas ranges are shipped from the factory set up to use natural gas. Any
Samsung gas range can be converted to use LP gas. Refer to page 52 in the User
Manual to contact a qualified service technician.
The conversion process should only be performed by a qualified LP gas installer.
Conversion instructions and LP orifices will be supplied with the LP conversion kit.
The conversion to LP requires all burner orifices to be changed (5 surface burners
and 2 oven burners).
In addition, the nozzle on the gas pressure regulator needs to be reversed. All
replaced orifices must be left with the consumer, including the instructions and
retrofit sizes and orifice indication.
NX58*665***
BURNER ORIFICE SIZES AND OUTPUT RATINGS (LP Gas [Propane] 10 in WCP)
Burner Location
RF
LF
RR
LR
CTR
BROIL
BAKE
BURNER ORIFICE SIZES AND OUTPUT RATINGS (Natural Gas 5 in WCP)
Burner Location
RF
LF
RR
LR
CTR
BROIL
BAKE
22 English
Install_NX58M6650WS_DG68-00992A-05_EN+MES+CFR.indb 22
BTU Rate
Orifice Size [mm]
14,500
In 0.46 / Out 0.74 (2 pcs)
11,500
1.04
4,000
0.62
7,500
0.83
7,500
0.83
11,500
1.02
15,000
1.15
BTU Rate
Orifice Size [mm]
20,000
In 0.85 / Out 1.29 (2 pcs)
15,000
1.78
5,000
1.01
9,500
1.40
10,000
1.40
13,500
1.64
18,000
1.90
NX58*663***
BURNER ORIFICE SIZES AND OUTPUT RATINGS (LP Gas [Propane] 10 in WCP)
Burner Location
BTU Rate
RF
14,500
LF
11,500
RR
4,000
LR
7,500
CTR
7,500
BROIL
11,500
BAKE
15,000
BURNER ORIFICE SIZES AND OUTPUT RATINGS (Natural Gas 5 in WCP)
Burner Location
BTU Rate
RF
18,000
LF
16,000
RR
5,000
LR
9,500
CTR
10,000
BROIL
13,500
BAKE
18,000
Orifice Size [mm]
1.12
1.04
0.62
0.83
0.83
1.02
1.15
Orifice Size [mm]
1.94
1.88
1.01
1.40
1.40
1.64
1.90
2018-12-19
6:12:45