3.

SET UP INSTRUCTIONS

The blower comes packaged as follows:
intake of blower closed for protection.
Intake
#700
silencer
assembled together, but separate from blower.
Packet containing #424 gasket, 4 x #904 screws and key
ch13.
3.1
START-UP WITH 90° MANIFILD
For final assembly and to put in operation, proceed as
follows:
1.
Remove the protective plug in intake manifold port.
2.
Place #424 gasket on intake port.
3.
Select the desired orientation (see Fig. 1, Fig. 2, Fig. 3).
906
700
424
706
424
904
housing
and
manifold
#706
Fig.1
Fig.4 - Version without 90° manifold
4.
Place the #706 manifold with the #700 silencer housing on
#424 gasket and seal all the way around with #426 screws
using the key (ch13) as provided.
3.2
START-UP WITHOUT 90° MANIFILD
Using the blower without the 90° manifold (ref. Fig. 4)
1.
Disassemble the #706 manifold from the intake housing,
removing the #906 bolts.
2.
Place the #424 gasket on the intake port of the blower.
Place the #700 silencer housing on #424 gasket and seal
3.
all the way around with #904 screws using the key (ch13)
as provided.