OPERATION WITH DIFFERENT TYPES OF GAS
CONVERSION FROM NATURAL GAS TO B/P
Should you wish to adapt a natural gas burner for combustion of other gases observe
the following instructions.
Move the ring nut A situated on
the supply pipe B towards the
diffuser C, so as to reduce the
gas outlet holes.
MAINTENANCE
Skilled staff has to perform yearly the following
operations:
- Check the valve inside tightness.
- Filter cleaning.
- Fan and head cleaning.
- Check the position of the ignition electrode
tips as well as the control electrode.
- Calibrate the air and gas pressure switches.
- Check the combustion by means of CO
FUMES TEMPERATURE bearings.
- Check all the gaskets and seal tightness.
Close the fuel aspiration gate and, depending
on the type, proceed with thorough cleaning of
the filtration component. To check whether the
air gate fan is clean or to check the combustion
head proceed as follows:
- Remove the cover (1) by loosening the screw
(2).
- Loosen the lower screws (3) completely (fig.1).
- Parzially loosen the upper screws (4) too
(fig.2).
- Release by raising the component support
plate (5) and hook it in its seat as illustrated in
UK
figure 3
40
The ring nut locking screw must be in the elec-
trodes area
Bring the ring nut into contact
with the diffuser
-CO-
2
M
M