The models T-ONE3B and T-ONE5B, with the optionals batteries
power supply guarantee normal automation operation also in the
event of a power failure.
Note that this is an automatic device and mains powered, and
therefore when used the due precautions must be taken. The fol-
lowing in particular is recommended:
•
Never touch the device with wet hands and/or wet or bare feet;
•
Disconnect the power supply before opening the controls box
and/or gearmotor;
•
Never touch the motor before ensuring it is completely cool;
•
Only move the gate when it is completely visible;
•
Keep away from the operating range of the gate when in move-
ment: wait until it is stationary;
•
never allow children or animals to play in the vicinity of the
gate;
•
never allow children or unskilled persons to use the remote
control or other activation devices;
•
Perform periodic maintenance;
•
In the event of a fault, disconnect the power supply and only
move the gate manually when possible and in safety. Do not
intervene on the gate; call an authorised technician for assis-
tance.
CLEANING OF THE AUTOMATION WITH WATER JETS
OR SIMILAR DEVICES IS STRICTLY PROHIBITED. NEV-
ER DIRECT WATER JETS DIRECTLY ONTO THE AUTO-
MATION.
11_
MAINTENANCE
The gearmotors in the T-ONE series are low maintenance prod-
ucts. However efficient operation also depends on the condition of
the gate: Therefore a number of simple operations are described
below to maintain gate efficiency.
Caution: No person other than the maintenance engi-
neer (who must be a specialised technician) must be
allowed to operate the automatic gate during mainte-
nance.
Therefore disconnect the device from the power mains to avoid the
risk of electric shock. However, if the power supply is required for a
number of checks, ensure that the control devices are controlled or
disabled (remote controls, pushbutton panels etc.) with the excep-
tion of the device used by the maintenance engineer.
Routine maintenance
Each of the following operations must be performed when deemed
necessary and in any event every 6 months in the case of domestic
use (approx. 3000 work cycles) and every 2 months in the case of
intensive use, e.g. apartment block (every 3000 work cycles).
Gate
-
Lubricate (with a grease pump) the gate sliding wheels;
-
Check the condition and stability of the rack;
Automation system
-
Check operation of the safety devices (photocells, pneumatic
edge, torque limiter, etc..);
Special maintenance
If more complex operations are required on mechanical parts, the
gearmotor should be removed to enable repairs in the manufac-
turer's workshop by technicians or other authorised centre.
12_
OPTIONAL ACCESSORIES
The range of T-ONE motors can be completed with the following
optional accessories:
•
P-650ESE03 external manual release with armour-plated
case;
•
P-400FCM magnetic limit switch.
13_
NOISE LEVELS
Airborne noise generated by the gearmotor in normal operating
conditions is constant and does not exceed 70 dB.
14
14_
SCRAPPING
All materials must be disposed of in observance of current stand-
ards.
If the automation is to be scrapped there are no particular dangers
or risks associated with the automation itself.
In the case of material recovery, separate components according
to the waste category (electrical parts - copper - aluminium - plas-
tic, etc.).
15_
DISASSEMBLY
If the automation is disassembled for subsequent re-assembly in
another site:
-
Disconnect the power supply and the entire electrical system;
-
Remove the gearmotor from the fixing base;
-
Disassemble all system components;
-
If some components cannot be removed or are damaged, re-
place.
16_
MALFUNCTIONS TROUBLESHOOTING
The gate does not open, the motor does not work.
-
Check that the photocells or sensitive edges are not dirty, en-
gaged or misaligned. Proceed according to the case in hand
-
Check that the electrical equipment is powered correctly, check
all fuses.
-
Check that all functions are correct via the control unit diagnos-
tic leds (see relative instructions). Locate the cause of the fault.
If the leds indicate that a start command persists, check that
there are no radio controls, start pushbuttons or other devices
that keep the start contact activated (closed).
-
If the control unit does not work, replace.
If results are negative after the above proposed solutions, replace
the gearmotor.
The gate does not open, the motor turns but there is no move-
ment.
-
The manual release is still engaged. Restore power operated
functions.
-
Check that the gate is up against the mechanical limit stops.
Manually release the gate, move it and restore power-operat-
ed functions. Check and correct the position of the limitswitch
pads.
-
Check that there are no defects in mechanical set-up of the
gate.
If results are negative after the above proposed solutions, replace
the gearmotor.
T-ONE Series