General Purpose Filter
Installation
(Continued)
2. Securely mount the filter in a
vertical position as close as possible
to air tool connection.
3. Verify the arrow points to the
outlet. (See Figure 2.)
4. Install the unit with the same pipe
size as the piping in use. Avoid
using unnecessary fittings,
couplings, etc., that restrict airflow.
Use PTFE tape on all threads.
5. Connect the air supply to the inlet
port.
Operation
Before pressurizing system, make
certain the bowl is securely locked in
place by pushing it into the filter body
and turning clockwise to lock.
MATERIALS THAT ATTACK POLYCARBONATE PLASTIC (PARTIAL LISTING)
Acetaldehyde
Acetic acid (concentrated)
Acetone
Acrylonitrile
Ammonia
Ammonium flouride
Ammonium hydroxide
Ammonium sulfide
Anaerobic adhesives & sealants
Antifreeze
Benzene
Benzoic acid
Benzyl alcohol
Brake fluids
Bromobenzene
Butyric acid
Carbolic acid
Carbon disulfide
Carbon tetrachloride
Caustic potash solution
Caustic soda solution
Chlorobenzene
www.chpower.com
Maintenance
WARNING
!
Release all pressure before
attempting to install,
service, relocate or perform
any maintenance on the air
system. Personal injury and/or property
damage could occur.
Always depress-
WARNING
!
urize the unit
before removing the bowl. Personal
injury and/or property damage could
occur. If bowl is difficult to remove, it
may be under pressure.
1. Inspect and replace cracked,
damaged or deteriorated seals.
Wipe bowls with a soft, dry cloth to
clean. If bowl is damaged, unit must
be replaced.
Chloroform
Cresol
Cyclohexanol
Cylohexanone
Cyclohexene
Dimethyl formamide
Dioxane
Ethane tetrachloride
Ethyl acetate
Ethyl ether
Ethylamine
Ethylene chlorohydrin
Ethylene dichloride
Ethylene glycol
Formic acid (concentrated)
Freon (refrig. & propell.)
Gasoline (high aromatic)
Hydrazine
Hydrochloric acid (concentrated)
Lacquer thinner
Methyl alcohol
Methylene chloride
2
Model PA212103, KBA108, HDA706
2. Replace or clean filter element
periodically. Remove the filter
element and tap filter on a hard
surface or use an air gun to blow
out residual dirt.
3. Drain bowls at least once per work
shift. Pressure should be regulated
down to 30 psi max before drain is
opened. Rotate drain knob until
the arrow points downwards. To
avoid spray or splatter, cover
bottom of filter with a cloth and
turn the manual drain.
4. Before placing the unit in service,
make sure the bowl is reinstalled
and securely locked in place.
Technical Service
For information regarding the
operation or repair of this product,
please call 1-800-543-6400.
Methylene salicylate
Mike of lime (CaOH)
Nitric acid (concentrated)
Nitrobenzene
Nitrocellulose lacquer
Phenol
Phosphorous hydroxy chloride
Phosphorous trichloride
Phopionic acid
Pyridine
Sodium hydroxide
Sodium sulfide
Styrene
Sulfuric acid (concentrated)
Sulphural chloride
Tetrahydronaphthalene
Tiophene
Toluene
Turpentine
Xylene
Perchlorethylene and others