2.6.2 - Outdoor unit assembly
Proceed as follows (as described in the previous paragraph), once the ideal position for installation of the
a
b. Screw any clamping nuts, without tightening completely.
c. Using a spirit level, check the unit is level; if necessary, adjust the support feet.
d. Tighten any clamping nuts correctly.
IN = air inlet - OUT = air outlet
Model
"F1"
"F2"
e. If the outdoor unit is higher than the indoor units, to prevent rain entering, a downward bow must be made
along the connection pipe (siphon) before the connection pipe enters the wall. This is to guarantee that
the lowest point of the connection pipe is outdoors.