TROUBLE-SHOOTING
Fault condition 3
Crimping is completed. Cable cannot be pulled out.
Disconnect the mains supply from the
mc 25 and open cover.
1. Stop operation
Read counter (1) if required.
Press the reverse button (2) to move the mc 25
into start position.
Turn off (position 0) the mc 25 with mains
switch (3).
Disconnect mains cable (4).
2. Remove the tool insert
Slide back the cover (1).
Pull out the bolt (2).
Press lower stripping cutter (3) upwards and
remove the tool insert (4) sideways.
If it is impossible to remove the tool
!
insert then carry out step 4, else carry
on with step 3.
Remove end sleeve (5).
Bend cable aside (6)
10/12
Diagram 23
Stop operation
Diagram 24
Remove the tool insert
19