GLW MC25 Manual De Instrucciones página 61

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLE-SHOOTING
Fault condition 7
The mc 25 works too slow but counter works.
Remove mains fuses, disconnect the
mc 25 from mains!
 Pull out mains plug (1).
 Unscrew the fuse holder (2).
 Check the device fuses (3).
 Replace defective device fuses. The corre-
sponding article number is stated in chapter
spare parts.
 Insert device fuses into the fuse holder.
 Insert the fuse holder.
Fault condition 8
Crimp stamp or crimp forging die is defective.
Open the cover and disconnect the
mc 25 from mains supply!
 Pull out mains plug (1).
 Remove tool insert and end-sleeves feeder (see
also chapter retooling).
 Unscrew the allen screw (3) at defective crimp
stamp (2) or crimp forging die (1).
 Press the ring (4) down and remove the hose.
 Replace the defective part.
The corresponding article number is stated in
chapter spare parts.
Plastic parts must be clean and free of
grease!
10/12
Diagram 30
Check device fuses
Diagram 31
Replace crimp stamp /
crimp forging die
23

Publicidad

Tabla de contenido
loading

Productos relacionados para GLW MC25

Tabla de contenido