TDK-Lambda Vega 450 Instrucciones De Uso página 18

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 9
Vega 450 Handbook
H2/1L
5.6-9/1.8-3.8V
H2/1H
5.6-9/3.9-5.5V
H2/2
5.6-9/5.6-9V
H2/3
5.6-9/9.1-16.2V
H2/4
5.6-9/16.3-25V
H3/1L
9.1-16.2/1.8-3.8V
H3/1H
9.1-16.2/3.9-5.5V
H3/2
9.1-16.2/5.6-9V
H3/3
9.1-16.2/9.1-16.2V 10A/6A
H3/4
9.1-16.2/16.3-25V 10A/4.5A 162W/113W
H5/1L
16.2-31/1.8-3.8V
H5/1H
16.2-31/3.9-5.5V
H5/2
16.2-31/5.6-9V
H5/3
16.2-31/9.1-16.2V
H5/4
16.2-31/16.3-25V
Module
Output Voltage
L1
4.2 – 5.5V
W2
0.25 – 7.5V
W5 (STD)
0.25 – 32V
W5 (high
0.25 – 15V
current O/P)
15.01 – 32V
W8
1 – 48V
BB4
32.6 - 43V
CC3
18.2 - 32.4V
CC5
48.1 - 62V
DD4
28 - 43V
DD5
42 - 56V
EE2
7.6 - 16V
HH5/3
25.3 – 44.2V
HH5/4
32.5 - 53V
C5B4
43 - 48V
Z2
1.8 - 3.8V
(D1L+D1L)
Z3 (E1+E1)
1.8 - 3.8V
Z4
3.9 - 5.5V
(D1H+D1H)
Z6 (E2+D1H)
3.9 - 5.5V
Z7 (D3+D3)
8 - 16.5V
Z18 (L1+L1)
4.5 - 5.5V
Additional module limitations:
E2 module fitted in slots 4/5 is limited to 55A.
C1Y module can only be fitted in slot 1.
F2 module may only be fitted in slots 1/2 and is limited to 75A for ambient temperatures of greater than 45°C.
F1 module may only be fitted in slots 1/2.
For PSUs with three D modules fitted or two D modules and an E module fitted in slots 4 and 5:
D1L & D1H in slots 2/3 is limited to 42A and in slots 4/5 is limited to 47A
D2 in slots 2/3 is limited to 40A
The D2 module is limited to 8V when a digital secondary option is fitted.
PSUs fitted with a W2 module are limited to a maximum ambient of 45°C.
10A/8A
90W/31W
10A/8A
90W/44W
10A/6A
90W/54W
10A/6A
90W/98W
10A/4.5A 90W/113W
10A/8A
162W/31W
10A/8A
162W/44W
10A/6A
162W/54W
162W/98W
5A/8A
155W/31W
5A/8A
155W/44W
5A/6A
155W/54W
5A/6A
155W/98W
5A/4.5A 155W/113W
Rated
Power
Current
35A
193W
30A
225W
8.5A
272W
10A
150W
8.5A
272W
5A
240W
10A
430W
18A
583W
10A
620W
18A
774W
15A
840W
55A
880W
5A
221W
4.5A
238.5W
10A
480W
95A
361W
114A
433W
95A
523W
104.5A
575W
45.6A
752W
66.5A
366W
1
2/1
1
2/1
1
2/2
1
2/3
1
2/4
1
3/1
1
3/1
1
3/2
1
3/3
1
3/4
1
5/1
1
5/1
1
5/2
1
5/3
1
5/4
Occupied
Secondary
Slots
Turns
1
1
1
2
1
5
1
5
1
5
1
8
2
8
2
6
2
10
3
8
3
10
4
4
1
8
1
9
2
9
3
1/1
4
1/1
3
1/1
3.5
2/1
3
3/3
2
1/1
Page 18 of 35
20/8
15A/12A
20/8
15A/12A
20/12
15A/9A
20/18
15A/7.5A
20/18
15A/6A
30/8
15A/12A
>16V/N/A
30/8
15A/12A
>16V/N/A
30/12
15A/9A
>16V/N/A
30/18
15A/7.5A
>16V/N/A
30/18
15A/6A
>16V/N/A
25/8
7.5A/12A
25/8
7.5A/12A
25/12
7.5A/9A
25/18
7.5A/7.5A
25/18
7.5A/6A
Max
Setting for
Ampere
Current
Hazardous
Turns
Limit
35
43.8A
60
37.5A
42.5
10.6A
50
13.0A
42.5
10.6A
40
7.25A
80
12.5A
108
22.5A
100
12.5A
144
22.5A
150
18.75A
220
75A
40
7.5A
40.5
6A
90
12.5A
95/95
125A
114/114
150A
95/95
125A
209/104.5
137.5A
136.8/136.8
60A
66.5/66.5
87.5A
17138 issue 35, Sept 2019
-
-
-
-
-
-
-
-
-
-
Energy
>5.4V
>6.4V
>22.6V
-
>22.6V
>33V
>19.2V
>10.6V
>19.2V
>10.6V
>12.8V
>3.2V
>32V
>40V
>19.2V
>1.9V
>1.6V
>1.9V
>1.7V
>4V
>2.7V

Publicidad

Tabla de contenido
loading

Tabla de contenido