Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 9
Vega 450 Handbook

PRODUCTS COVERED

Unit Configuration Code:
V4 or Vega 450 range or Vega Smart (450W) or Vega Smart Plus (450W)
where V4 = Vega 450 Range
Vega Smart = Vega 450 PSU with primary digital option fitted
Vega Smart Plus = Vega 450 PSU with primary and secondary digital options fitted.
followed by: C, D, E, F, R, Q or P
where F = Standard fan, forward airflow
R = Standard fan, reverse air
Q = Quiet fan, forward airflow
P = Quiet fan, reverse air
C = Customer air
D† = Ruggedised fan, forward airflow
E† = Ruggedised fan, reverse air
† These fans must not be used for user accessible applications.
optionally followed by: F, I or S
where F = Fast-on or quick connect input terminals
S = Screw input terminals
I = IEC input
followed by: S, M, L, R, or T
where S = Standard Leakage (Class B Filter)
M = Medium Leakage
G = Moderate Leakage
L = Low Leakage
R = Reduced Leakage
T = Tiny Leakage
optionally followed by: E, F, EV, FV, EY, FY, xEW, xFW or D
where E = AC fail with PSU & fan enable and 5V aux supply
F = AC fail with PSU & fan inhibit and 5V aux supply
EV = AC fail with PSU & fan enable and 5V/300mA aux supply
FV = AC fail with PSU & fan inhibit and 5V/300mA aux supply
EY = AC fail with PSU & fan enable, 5V/300mA aux supply and fan fail signal
FY = AC fail with PSU & fan inhibit, 5V/300mA aux supply and fan fail signal
xEW = AC fail with PSU & fan enable and 5-15V/1A aux supply, where x = voltage setting
xFW = AC fail with PSU & fan inhibit and 5-15V/1A aux supply, where x = voltage setting
D = Primary digital option. Provides PSU inhibit and enable, fan monitor, standby supply, hours of
operation, serial numbers, mains fail, over temperature warning. When secondary digital options
fitted also provides status bytes, unit and module IDs, grouping, digital voltage and current limit
programming, secondary inhibit and enable, secondary turn on delay, global and secondary module
good, module monitoring.
Modules:
B@, C@, C1Y, D@, E@, F1, F2, H@/@ or @_@, L@, W2, W5 & W8.
where the letter represents a module and @ is a number between 1 and 5, which represents the number of
turns on the transformer secondary. By reference to the following table, this in turn defines the permitted
voltage range of the module.
@ may optionally be followed by the letter L or H, where L and H indicate the low or high output voltage
variants of the module.
Page 15 of 35
17138 issue 35, Sept 2019

Publicidad

Tabla de contenido
loading

Tabla de contenido