INTERFACE
Right wheel
For power adjustment during manual operation and temperature adjustment during automatic operation. The opera-
ting mode may be set using the MENU key on the central panel. The display shows the power or temperature set.
Left wheel
For room air flow adjustment, which in any case cannot be set lower than the minimum necessary to ensure cooling of
the internal stove parts.
Panel 0/1 button
To turn the stove on or off and quit time programming (prog).
Panel MENU key
For switching the stove from manual to automatic operation and vice versa, and entering time programming
mode (prog).
"+" and "-" panel keys
For moving around in time programming mode (prog).
Display unit messages
Ac: ignition stage (flame appearance)
Ar: second ignition stage (flame stabilizing) before the operating stage
Of: shutdown stage (10 minutes)
P1 or P2 or P3: power level set
8-29: temperature set for automatic operation
H1..H7: stoppage problem identification number (see p. 23)
Pu: automatic combustion chamber cleaning under way
: motor stopping; wait a few tens of seconds before entering other commands.
When the stove is on standby, this flashes to show the mode it will restart in and when.
OPERATION
Before ignition.
1st Ignition: contact your Dealer, to calibrate the stove according to the pellets used and conditions of use.
The first few times the stove is ignited there may be a slight smell of paint, which disappears rapidly.
Before ignition, check:
==>
The stove has been installed correctly (see pages 17-18)
==>
The power supply
==>
The door is closed
==>
The combustion chamber is clean.
==>
The display shows standby (flashing power or temperature)
Hold the 0/1 key down for at least two seconds: the stove will automatically start loading pellets to start combustion (the
display shows Ac). No flames appear for the first few minutes.
Ac changes into Ar when the flame appears.
SCREW FEEDER LOADING
If the pellet hopper empties completely, press the + and - keys together to fill the screw feeder.
This must be done before igniting the stove again if it has shut down due to running out of pellets.
It is normal for a few pellets to be left in the hopper, which the screw feeder is not able to pick up.
IGNITION
Automatic ignition
Hold the 0/1 key down for two seconds with the stove on standby to start the ignition procedure. Ac appears on the display
for a few minutes (the ignition procedure does not actually take a preset time: it is automatically shortened if the electro-
nics detect that certain tests are passed). The flame appears after about five minutes. It is normal for a little smoke to be
seen in the combustion chamber before the flame appears. "Ar" appears on the display until the flame stabilizes.
20