FUNCTIONAL DESCRIPTION
CAUTION:
Always be sure that the tool is switched off and the
•
battery cartridge is removed before adjusting or
checking function on the tool.
Installing or removing battery cartridge
1
2
012695
CAUTION:
Always switch off the tool before installing or
•
removing of the battery cartridge.
Hold the tool and the battery cartridge firmly when
•
installing or removing battery cartridge. Failure to
hold the tool and the battery cartridge firmly may cause
them to slip off your hands and result in damage to the
tool and battery cartridge and a personal injury.
To remove the battery cartridge, slide it from the tool
while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the
battery cartridge with the groove in the housing and slip it
into place. Insert it all the way until it locks in place with a
little click. If you can see the red indicator on the upper
side of the button, it is not locked completely.
CAUTION:
Always install the battery cartridge fully until the red
•
indicator cannot be seen. If not, it may accidentally fall out
of the tool, causing injury to you or someone around you.
Do not install the battery cartridge forcibly. If the
•
cartridge does not slide in easily, it is not being
inserted correctly.
Battery protection system
(Lithium-ion battery with star marking)
1
012128
1. Red indicator
2. Button
3. Battery cartridge
3
1. Star marking
Lithium-ion batteries with a star marking are equipped
with a protection system. This system automatically cuts
off power to the tool to extend battery life.
The tool will automatically stop during operation if the tool
and/or battery are placed under one of the following conditions:
Overloaded:
•
The tool is operated in a manner that causes
it to draw an abnormally high current.
In this situation, release the switch trigger on
the tool and stop the application that caused
the tool to become overloaded. Then pull the
switch trigger again to restart.
If the tool does not start, the battery is
overheated. In this situation, let the battery
cool before pulling the switch trigger again.
Low battery voltage:
•
The remaining battery capacity is too low and
the tool will not operate. In this situation,
remove and recharge the battery.
Indicating the remaining battery capacity
(Only for battery cartridges with "B" at the end of the
model number.)
015676
Press the check button on the battery cartridge to
indicate the remaining battery capacity. The indicator
lamps light up for few seconds.
Indicator lamps
Lighted
Off
015658
5
1. Indicator lamps
2. Check button
1
2
Blinking
75% to 100%
50% to 75%
25% to 50%
Charge the
The battery
malfunctioned.
Remaining
capacity
0% to 25%
battery.
may have