8.2.2. Filter insert
Replace filter insert at least every 6 month.
1. Close shutoff valve on inlet and outlet
2. Release pressure on outlet side
3. Unscrew filter bowl
4. Remove filter cartridge
5. Insert new filter cartridge in filter bowl
6. Screw filter bowl in place
7. Open shut-off valve on inlet
8. Slowly open shutoff valve on outlet

10. Troubleshooting

Problem
Too little or no water pressure

11. Spare Parts

FF20
1
No. Description
Dimension
1
Replacement filter
Cartridge Height 10"FF20-DMF
cartridge 25µm
2
Replacement active
Cartridge Height
carbon cartridge
10"
MU1H-1142GE23 R0114
Cause
Shut-off valves up- or downstream are not
fully open
Filter cartridge is contaminated
Filter is not fitted in flow direction
FF40
2
1
Part No.
FF20-GAC
GB

9. Disposal

• Head and ring nut: reinforced polypropylene
• Polypropylene fine filter
• Clear synthetic material filter bowl
• EPDM O-rings
Die örtlichen Vorschriften zur ordnungsgemäßen Abfall-
verwertung bzw. Beseitigung beachten!
Remedy
Open the shutoff valves fully
Replace filter cartridge
Fit filter in flow direction