1.2. Standard supplied accessories

U-5MX3
Gas line piping (1)
Gas line piping (2)
Gas line piping (3)
Installation manual
1
Operation manual
1
Additional refrigerant charge
1
label
Refer to figure 20.
1
Installation and operational manual
2
Accessory pipes

1.3. Optional accessories

To install the above outdoor units, the following optional parts are
also required.
Refrigerant branching kit (for R-410A only: Always use an
appropriate kit dedicated for your system.)
Refnet header
CZ-P29HK12Q
CZ-P64HK12Q
CZ-P75HK12Q
U-5~48MX3XPQB
Urban Multi air conditioner
4PW21867-1A
Total capacity of
Total quantity of
indoor units
indoor units
62.5
~
162.5
8
100
~
260
13
125
~
325
16
150
~
390
19
175
~
455
20
200
~
520
20
225
~
585
20
250
~
650
20
275
~
715
22
300
~
780
32
325
~
845
32
350
~
910
32
375
~
975
32
400
~
1040
32
425
~
1105
34
450
~
1170
36
475
~
1235
38
500
~
1300
40
525
~
1365
40
550
~
1430
40
575
~
1495
40
600
~
1560
40
U-8~16MX3
1
1
1
1
1
1
Refnet joint
CZ-P20BK12Q
CZ-P29BK12Q
CZ-P64BK12Q
CZ-P75BK12Q
Outdoor unit multi connection piping kit (For R-410A only:
Always use an appropriate kit dedicated for your system.)
Number of outdoor units connected
2
CZ-32PJ2PQ
To select an optimum refrigerant branching kit, refer to "6. Refrigerant
piping" on page 4.
1.4. Technical and Electrical specifications
Refer to the Engineering Data Book for the complete list of
specifications.
2. M
AIN COMPONENTS
For main components and function of the main components, refer to
the Engineering Data Book.
3. S
ELECTION OF LOCATION
This is a class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to
take adequate measures.
This unit, both indoor and outdoor, is suitable for
installation
in
a
commercial
environment. If installed as a house-hold appliance it could
cause electromagnetic interference.
Make sure to provide for adequate measures in order
to prevent that the outdoor unit be used as a shelter
by small animals.
Small animals making contact with electrical parts can
cause malfunctions, smoke or fire. Please instruct the
customer to keep the area around the unit clean.
The inverter units should be installed in a location that meets the
following requirements:
1
The foundation is strong enough to support the weight of the unit
and the floor is flat to prevent vibration and noise generation. If
not, the unit may fall over and cause injury.
2
The space around the unit is adequate for servicing and the
minimum space for air inlet and air outlet is available. (Refer to
figure 1 and choose one of the possibilities).
In case of an installation site where only the sides A+B have
obstacles, the wall heights have no influence on any indicated
service space dimensions.
A B C D
Sides along the installation site with obstacles
Suction side
3
There is no danger of fire due to leakage of inflammable gas.
4
Ensure that water cannot cause any damage to the location in
case it drips out the unit (e.g. in case of a blocked drain pipe).
5
The piping length between the outdoor unit and the indoor unit
may not exceed the allowable piping length. (Refer to
"6.3. Example of connection" on page 8)
6
Select the location of the unit in such a way that neither the
discharged air nor the sound generated by the unit disturb
anyone.
7
Make sure that the air inlet and outlet of the unit are not
positioned towards the main wind direction. Frontal wind will
disturb the operation of the unit. If necessary, use a windscreen
to block the wind.
3
CZ-48PJ2PQ
and
light
industrial
Installation manual