Installation
Semi-Recess and Recess-Mounted Towel/Waste Unit
NOTE: For surface-mounted unit, refer to the instructions on page 2.
NOTE: Coordinate installation with architect and contractor to avoid protrusion
from opposite wall, pipes vent, conduits, electrical wiring etc. in wall. Grounding
is recommended for plaster wall installation. If installing where unit projects
above top of wainscot, provide aluminum channel or other filler to prevent gap
from finished wall and flange of unit. For block walls, use metal expansion
shields (not provided).
1. Provide the wall opening per the dimensions shown in Figure 1.
2. Position the unit into the opening, unlock the door and remove the waste can.
NOTE: Shims may be required to prevent distortion when positioning the unit into
the wall opening. Place shims at the mounting holes between the outside of the
unit and the wall before securing the towel/waste unit.
3. Secure the unit to wall through the concealed mounting holes provided with
the four #10 screws supplied.
Figure 1
7-21/64"
(186mm)
54-3/32"
(1374mm)
50-3/64"
(1271mm)
7-35/64" (192mm)
P20-139 Rev. A; EN 05-1512
© 2005 Bradley Corporation
Page 1 of 6
3/9/05
15-1/4" (387mm)
54-5/8"
(1385mm)
4-37/64"
(116mm)
7-21/64" (186mm)
236 Towel/Waste Unit with Center Pull
For ADA Accessibility compliance
• the unit should be installed so
15-3/4"
(397mm)
• the unit cannot be located
6'-5" MAX
(1956mm)
TO
5'-2" MIN
(1575mm)
P.O. Box 309, Menomonee Falls, WI 53052-0309
Phone: 1-800-BRADLEY Fax: (262) 251-5817
http:\\www.bradleycorp.com
IMPORTANT
that the top of the wall opening
is 73" (1854mm) maximum
above the finished floor (AFF)
if additional clear-floor side-
reach access is provided, OR
67" (1701mm) maximum AFF if
only clear-floor forward-reach
access is provided.
where it will protrude into
walks, halls, corridors,
passageways or aisles.