Installation
Installation
Surface-Mounted Towel/Waste Unit
NOTE: For semi-recess and recess-mounted unit, refer to the instructions on
page 1.
IMPORTANT: Adequate in-wall backing must be provided by installer to
fully support the weight of the unit. Always check local codes and
ordinances prior to installation.
IMPORTANT: Concealed mounting holes in back of the unit must be
provided by installer prior to installation. Refer to Figure 2 for suggested
mounting hole locations.
1. Plaster or dry wall construction: Provide in-wall backing (suitable for use
with #10 x 1" screws) at the mounting slot locations shown in Figure 2
below.
Other wall surfaces: Provide fiber plugs or expansion shields (suitable for
use with #8 x 1-1/4" sheet-metal screws supplied by installer), OR provide
1/8" toggle bolts or expansion bolts. If installing where unit projects above top of wainscot,
provide aluminum channel or other filler to prevent gap from finished wall to back of unit. For
block walls, use metal expansion shields (provided by installer).
2. Unlock the door and remove the waste can. Secure the unit to the wall through the concealed
mounting holes (provided by installer) with the hardware appropriate for your wall construction.
Figure 2
(1422mm)
* Suggested mounting hole
Bradley Corporation • P20-139 Rev. A; EN 05-1512
17-1/8"
(435mm)
56"
51"
(1295mm)*
8-1/2"
(216mm)*
2-1/4"
(57mm)*
locations for installer
42-1/2"
(1080mm)
CENTERLINE
OF BACKING
7-5/8"
(194mm)
14-13/16"
(376mm)*
4" TYP
(102mm)
CENTERLINE
OF BACKING
TO FLOOR
5'-0" MIN
(1524mm)
TO
6'-3" MAX
(1905mm)
17-1/8"
(435mm)
3/9/05
236
2