Performance Data Sheet -Cont'd
Performance Claims
This system has been tested according to
NSF/ANSI 53 for VOC reduction* and to 58 for
reduction of the substances listed below, and
to NSF/ANSI 372 for lead free compliance.
The concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal
to the permissible limit for water leaving the system as specified in
NSF/ANSI 53 and 58. This system has been tested for the treat-
ment of water containing pentavalent arsenic (also known as As
(V), As (+5), or arsenate) at concentrations of 0.30 mg/L or less.
This system reduces pentavalent arsenic, but may not remove
AVERAGE
INFLUENT
(MG/L)
Arsenic (Pentavalent)
0.31
Barium
9.2
Cadmium
0.031
Chromium
0.3
(Hexavalent)
Chromium (Trivalent)
0.3
Copper
3.2
Cyst
92,000 / ml
Fluoride
8.7
Lead
0.15
Perchlorate
130
Radium 226 / 228
25 pCi/L
Selenium
94.85
TDS
770
Turbidity
11.3
Nitrate / Nitrite
N/A
*VOC (as chloroform)
288
Recovery- 25.5%
Depending on water chemistry, water temperature, and water pressure
Watts R.O. Systems production and performance will vary. Efficiency
rating means the percentage of the influent water to the system
that is available to the user as reverse osmosis treated water under
operating conditions that approximate typical daily usage. Recovery
rating means the percentage of the influent water to the membrane
portion of the system that is available to the user as reverse osmosis
treated water when the system is operated without a storage tank or
when the storage tank is bypassed. There is an average of 4 gallons
of reject water for every 1 gallon of product water produced.
AVERAGE
% REDUCTION
EFFLUENT
(MG/L)
0.001
98.80%
0.08
97.60%
0.0004
95.70%
0.002
98.50%
0.001
96.70%
0.02
98.70%
3 / ml
99.97%
0.19
95.70%
0.002
95.70%
2.8
96.90%
5 pCi/L
80%
< 0.2
96.50%
35
96.40%
0.1
99%
N/A
83.30%
0.5
99.80%
Daily Production Rate-23.5 GPD
other forms of arsenic. This system is to be used on water supplies
containing a detectable free chlorine residual at the system inlet
or on water supplies that have been demonstrated to contain only
pentavalent arsenic. Treatment with chloramine (combined chlorine)
is not sufficient to ensure complete conversion of trivalent arsenic
to pentavalent arsenic, Please see the Arsenic Facts section for
further information.
PH
PRESSURE
7.24
50 psi
7.64
50 psi
7.49
50 psi
7.24
50 psi
7.64
50 psi
7.4
50 psi
7.44
50 psi
7.24
50 psi
7.39
50 psi
N/A
N/A
7.24
50 psi
7.24
50 psi
7.28
50 psi
7.43
50 psi
N/A
N/A
7.0-8.0
60 psi
12
MAXIMUM
INFLUENT
EFFLUENT
CHALLENGE
(MG/L)
CONCENTRATION
0.002
0.30 +/- 10%
0.12
10.0 +/- 10%
0.0008
0.03 +/- 10%
0.004
0.03 +/- 10%
0.002
0.03 +/- 10%
0.04
3.0 +/- 10%
18
min. 50,000/ml
0.3
8.0 +/- 10%
0.005
0.15 +/- 10%
N/A
N/A
5 pCi/L
25 pCi/L
< 0.2
0.10 +/- 10%
26
750 +/- 40 mg/L
0 - 1
11 +/- 1 mg/L
N/A
N/A
0.5
300 +/- 30
Efficiency-12.8%
MAXIMUM
ALLOWABLE
CONCENTRATION
(MG/L)
0.010
2.0
0.0005
0.1
0.1
1.3
N/A
1.5
0.0107
N/A
5 pCi/L
0.05
187
0.5 NTU
N/A
0.5