BML SGA-AEZ1-LZZZ-TU11-S284
Absolute Magnetically Coded Position Measuring System
Construction and function (continued)
Connectors S284
The electrical connection is made using a connector.
If the sensor is powered by a source separate
from the processing electronics, the grounds of
the sensor and processing electronics must be
connected.
Pin assignment of S284 plug (M12, 12-pin), view from
above on sensor head)
Pin
1
2
3
4
5
6
7
8
9
10
11
12
Shield
1) Unassigned leads must not be connected.
2) If not used, then connect to GND (recommended) or leave unconnected.
3
english
Signal
VDD
+Temp
GND
–TX
+Tx
Not used
1)
–RX
+Rx
Not used
1)
–Temp
Preset
Not used
1)
Shield
Description
Supply voltage 10...30 V DC
Temperature input
Sensor ground (0 V)
Send DRIVE-CLiQ signals
Send DRIVE-CLiQ signals
Receive DRIVE-CLiQ signals
Receive DRIVE-CLiQ signals
Temperature input
Digital input
2)
, sets the current position to approx. 10 mm
(Connector housing to) shield

Publicidad