Firman W03661OF Manual Del Operador página 28

Generador inversor portátil
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Inspect Muffler and Spark Arrester
1.Inspect the muffler for cracks, corrosion, or other damage.
2.Remove the screws securing the spark arrester in place and then remove it from muffler.
3. Carefully remove the carbon deposits from the spark arrester screen with a wire brush.
4. Replace the spark arrester if it is damaged. If replacement parts are required, make sure to use
only FIRMAN original equipment replacement parts.
5. Position the spark arrester in the muffler and attach with the screws.
NOTICE Failure to clean or replace spark arrester may result in decreased engine performance.
GENERATOR MAINTENANCE
Run the generator at least 30 minutes every month.
Make certain that the portable generator is kept clean and dry.
Do not expose the unit to excessive dust, dirt, moisture or corrosive vapors.
Do not insert any objects through cooling slots.
Before each use inspect underneath the generator for signs of oil or fuel. Clean any accumulated
debris. Keep area around muffler free from any debris. Use a soft bristle brush to remove dirt or
caked on oil. Use a damp cloth to clean all exterior surfaces.
English
Maintenance - Storage
26
Customer Service: 1-844-FIRMAN1

Publicidad

Tabla de contenido
loading

Tabla de contenido