ASSEMBLY AND DISASSEMBLY

Follow standard engineering practices and
refer to figure for the mounting of component
subassemblies.
According to Directive 2012/19/
EC concerning Waste Electrical and
Electronic Equipment (WEEE), this
product must be recycled. Please
contact your "Customer Centre" or
consult the website
"www.desouttertools.com" to find out
where you can recycle this product.

ERROR CODES

Error
4 red flashing lights Clutch sensor error. The
5 red flashing lights Exceeding of the maximum
6 red flashing lights Tool overheating. The tool
7 red flashing lights Battery voltage fault. The
8 red flashing lights Overcurrent on the power
9 red flashing lights Motor stall.
At start-up, after
switch-off the white
LED, the LED
flashes 3 times (red
color)
(1 flash/second).
09/2019
Description
tool does not start or stops
instantaneously.
temperature (70°C). The
tool does not start or stops
instantaneously.
does not start or stops
instantaneously.
tool does not start or stops
instantaneously.
circuit. The hardware limit
has been reached. The
tool does not start or stops
instantaneously.
The motor is not able to run
the screw.
Backup configuration has
been restored.
Validation / Action
The signal given by the clutch sensor is out of
tolerances. Check the sensor and the magnets
joined to the sensor. Check the flex is correctly
connected to the electronic board. If the fault still
appears, contact our customer service.
The temperature measured with the electronic
board is higher than 70°C. Wait for the tool
cool down. The tool can tighten again when
the temperature is lower than approximately
70°C. Decrease the tool rate. If the temperature
is lower than 70°C and the fault still appears,
contact our customer service.
The power requested is too big. Do not use
the tool as a drilling machine. If the fault still
appears, contact our customer service.
The fault means that the battery voltage is not
appropriate for the voltage announced in the
tool. Make sure that the tool is adapted for the
battery used. If the battery used is correct=>
contact our customer service.
This problem can result from a use requiring
a too big power for the tool. If the fault still
appears, the power stage is faulty => contact our
customer service.
The tool can still be used.
The fault means that the torque set on the clutch
is above the motor capacity.
This error generally happens at low speed or
after a rehit action.
Reduce the clutch torque or increase the motor
speed.
The user is not affected by this issue.
The tool can be used without restriction.
This error appears if the backup configuration
has been restored after corruption.