Type of Error
Overheated
Pressure Sensor Defective
Heating Sensor Defective
Temperature Sensor
Defective
Printer not Ready
(only label tag printer)
Download Cancelled
Memory Full
c. Welding Process
Temperature low
Temperature high
Error Changeover
Error Drag Pressure
Error Build-up Pressure
Error Heat Soak Pressure
Error Joining Pressure
Cooling Stopped
Error Plate Temperature
4.6
Using ViewWeld to View Welding Reports and Print Tags
The ViewWeld feature offers viewing an abstracted version of the
welding report recorded during the last welding process and print-
ing it as a label tag to be affixed to the joint on the optionally avail-
able tag printer. The ViewWeld abstract shows the report number,
the date and time of the welding and the welding parameters along
with an evaluation of the quality of the joint/welding operation (see
Display 33).
To call the ViewWeld abstract of a welding report, press the ñ key in
the start screen (see Display 3). To print a tag of this operation, press
the START/SET key in the ViewWeld screen.
After the ViewWeld abstract was accessed, it is possible to browse
through all abstracts in memory by pressing the ï and ð keys.
5
Downloading the Reports
Interface
USB A Interface Port
for connecting USB mass storage media (such as a memory
stick)
Version July 2020
The temperature of the control and hydraulic unit is too hot. Let the
welding system cool down for about 1 hour.
The sensor indicated on the display (hydraulic pressure, heating
element temperature, ambient temperature) is defective; where
possible, check the connections/plug; have the machine inspected by
an authorized service shop if needed.
The optional printer is not ready (possible reasons also: no
communication or faulty cable).
During data transfer or printing, an error condition occurred which
could not be cleared.
The system memory is full of welding reports. Print or download the
reports in memory or switch memory control off. Without memory
control, a new report overwrites the oldest existing one.
Heating element temperature will be increased automatically.
Heating element temperature will be reduced automatically.
It took too long to retract the heating plate and bring the pipes to
joining; welding will have to be repeated.
Impossible to determine the drag pressure; maybe pipes will have to
be clamped once again; or the pressure is below 1 bar, which is not
feasible for technical reasons.
Build-up pressure too high or too low and was not re-adjusted in
time.
Heat-soaking pressure too high and was not re-adjusted in time.
Joining pressure too high or too low and was not re-adjusted in
time.
Operator has stopped the cooling time by pressing the STOP/REST
key.
Heating element temperature is out of tolerance; impossible to
re-adjust the temperature; maybe the ambient temperature was too
low.