Automatic regulation of the
air flow rate
Proflow
SC 120 minimum 120 l/min
2
Proflow
SC 160 minimum 160 l/min
2
Proflow
120
minimum 120 l/min
3
Proflow
180
minimum 180 l/min
3
Selection of blower-assisted breathing protector equipped with filter
(In Australia and New Zealand, see the next page for the limitations of AS/NZS 1716:2012.)
Type of protective device
Power-assisted half mask with
particle filter
Power-assisted full face mask
with particle filter
Power-assisted face shield or welding shield
with particle filter
Device with combined filter
Power-assisted half mask with gas filter *)
TM2 gas filter class 1, 2 or 3
Power-assisted full face mask with gas filter
*)
TM3 gas filter class 1, 2 or 3
Power-assisted face shield or welding shield
with gas filter *)
TH1 gas filter class 1 or 2
TH2 gas filter class 1 or 2
TH3 gas filter class 1 or 2
*) Provided that the maximum permissible detrimental gas concentration for the gas filter is not
exceeded. For power-assisted filtering devices with gas filter, concentration must not exceed
0.05 vol.% in gas filter class 1 and 0.1 vol.% in gas filter class 2 and 0.5 vol.% in gas filter class 3.
**) If national guidelines exist: in all cases the lowest value applies.
AUSTRALIA AND NEW ZEALAND
AS/NZS 1716:2012
Selection considerations – Powered air purifying respirator (PAPR) *)
PAPR fitted with
PAPR Filter type
Full facepiece
PAPR – P3 Particulates
PAPR – Gas filter Class 1 Up to 10 to a maximum concentration of 1000 ppm
Half hood style
PAPR – P1 Particulates
PAPR – Gas filter Class 1 Up to 10 to a maximum concentration of 1000 ppm
Full hood & blouse PAPR – P1 Particulates
PAPR – Gas filter Class 1 Up to a maximum concentration of 1000 ppm
*) Contact the Scott Safety Customer service for more detailed information on filter selection,
appropriate maximum use concentration levels or AS/NZS 1715:2009 Selection, use and
maintenance of respiratory protective devices or to relevant local authorities for further guidance.
Scott Health & Safety
137 McCredie Road
Guildford NSW 2161
Ph: (02) 8718 2200
Fax: (02 8718 2211
Operating time on fully
charged battery
minimum 4 hours
minimum 4 hours
minimum 4 hours
minimum 4 hours
Multiples of threshold concentration **) Remarks, limitations
APF (Assigned protection factor)
BS 4275 (GB)
BGR 190-ZH1/701(DE)
TM2P
20 100
TM3P
40 500
"Open" facepieces, such as helmets or hoods,
do not provide sufficient protection in case of
breakdown or inferior output of the blower.
TH1P
10
5
Therefore, devices of class TH1 must never be
TH2P
20 20
used against carcinogenic, very poisonous or
TH3P
40 100
radioactive gases and vapours.
The specified multiples of threshold value for the gas or
particle filters are given separately, but in all cases the
lowest value applies.
20 100
40 500
For devices with combined filter apply the
relevant limitations of gas and particle filters.
10
5
20 20
40 100
Minimum protection factor
100+
Up to 10
10
13
Weight of the blower
device without filters
1,590 kg
1,590 kg
1,810 kg
1,810 kg
Proflow