11
TECHNICAL SPECIFICATIONS
11
Technical specifications
Laser class
Sensing range
Sensing range max.
Light spot diameter/distance
Supply voltage U
B
Output current I
max.
Switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
1)
Object with 90 % remission (based on standard white DIN 5033)
2)
Limit values. U
connections reverse-polarity protected. Residual ripple max 5 V
B
3)
With light / dark ratio 1:1
4)
Signal transit time with resistive load
5)
Reference voltage DC 50 V
6)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
C = Interference suppression
11.1
Dimensional drawing
12
12
3
(0.47)
(0.02)
2
1
Figure 3: Dimensional drawing
PP
0.5
21
4
(0.83)
4
3
(0.12)
9.7
(0.38)
1
5 ... 400 mm
0 ... 450 mm
1)
0.4 mm / 150 mm
DC 10 ... 30 V
2)
30 mA
1,000 Hz
3)
0.625 ms
4)
IP67
II
5)
A, B, C
6)
-20 ... +50 °C
8025471 / 24.06.2020 | SICK
Subject to change without notice
18.3
(0.72)