7.3
Settings
8025471 / 24.06.2020 | SICK
Subject to change without notice
Operating reserve
100
3
90 %
10
2
18 %
1
0
0
100
200
(3.94)
(7.87)
Figure 2: GTE6L
Sensing range on black, 6% remission
1
Sensing range on gray, 18% remission
2
Sensing range on white, 90% remission
3
Sensing range setting
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
The sensitivity (sensing range) is adjusted with the potentiometer (type: 5-turn). Clock‐
wise rotation: sensitivity (sensing range) increased; counterclockwise rotation: sensitiv‐
ity (sensing range) reduced. We recommend placing the object within the sensing
range, e.g. see
figure
X. Once the sensitivity is set, remove the object from the beam
path. The switching output changes.
Table 3: Adjustment sensing range
1
6 %
300
400
500
(11.81)
(15.75)
(19.69)
Distance in mm (inch)
7
COMMISSIONING
9