MENU RELAY (OPTIONAL)

The relay output indicates the presence of an alarm. It is a dry contact. The relay reports an alarm by closing the contact
or by opening it (default is N.O). See the following paragraph, "Alarm". In the Relay menu it is possible to decide which
alarms can be reported by the relay.
IMPORTANT NOTE:
Level, Enable and Brok. Hose sensor are optional. If on your pump
they are not present you can not access the respective submenus
and in the menu will appear:
3sec

ALARM

DELAY ON

To INCLUDE OR EXCLUDE the other alarms follow the same steps of Delay On here above.
Rev 1.1
Press the ENTER/MENU button for 3 seconds to enter
programming.
Select by the cursor the menu Relay and press ENTER.
Use the ▼▲ buttons to move the cursor to the submenus.
Press ENTER to enter the submenu.
If you want to esc programming and return to measurement,
press the ESC button for 3 seconds.
In the menu Relay, select by the cursor "Alarm" and press
ENTER.
Select the desired operating mode of the relay with the ▼ ▲
buttons and press ENTER.
N.O = Normally Open (default value)
N.C = Normally Closed
If you want to esc programming and return to measurement,
press the ESC key for 3 seconds.
In the menu Relay, select by the cursor "Delay On" and press
ENTER.
Include or exclude this alarm by ▼▲ buttons and press
ENTER.
If you want to esc programming and return to measurement,
press the ESC key for 3 seconds.