10-11 Terminals for powering 24V (a.c.) accessories
10-5
Open gate indicator-light (socket rating: 24V - 3W max.)
W-E
Flashing light (socket rating: 230V - 25W max.)
U-V-W Motor "1" single-phase 230V (a.c.) delayed opening
X-Y-W Motor "2" single-phase 230V (a.c.) delayed closure
Activating the remote control
-Connect the antenna's RG58 cable to the apposite terminals.
-Lock the radiofrequency card into the electronic card
ries).
N.B.: the electronic card only recognises the radiofrequency card when the power is on.
Memorisation
A
-Keep the "PROG"
button on the electronic card pressed. The LED fl ashes.
-Press the transmitter button you wish to memorise. The LED will stay on to show memorisation has been successful.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
2-C1 Re-open during closing (N.C.) socket
1-2
Stop button (N.C. socket)
ES-ES (12V-15W max.) connection for electrically-actuated lock
2-7
Keyswitch and/or commands button (N.O.)
Connection of antenna
D
AFTER CUTTING OFF THE POWER SUPPLY (or after disconnecting the batte-