Backside
8.-16 pole multiconector (Harting) for Motor 1-4
9.- 4x CEE 4 pole 16A socket
10.- 1 CEE 5 pole 32 A Power Connector
Do not use a Harting connector in combination wit CEE sockets !!
When the chainhoist controller is Not used, always press the red button as a safety precaution. Remember, the
device is still connected to the mains power supply, so accidentally pressing the green Run button does not cause
any inmediate danger
W
ork instructions
1.- Measure the main power supply and make sure the operating voltaje is correct and all phases are present
2.. Connect the controller to the power supply
3.- Release the emergency button by turning it counter clockwise to switch the controller on.
4.- Connect the power cords to the controller by using a Harting 16P or a CEE connector.
5.- Check if the pre-selection switches for all hoist are in the "0" position
6.- Select a hoist and turn the switch in the up (1) or down (2) position. Press the run button for 2 seconds to make
sure the hoist has power. Also make sure that the running direcction of the hoist matches the selected direction on
your controller. he green LED lights up, when the green RUN button is pressed. When the RUN button is released,
the green LED immediately dims.
7.- If the direction of the hoist is not correct, change the phases
Manual de usuario / User Manual | FR-419 Chainhoist controller | Rev. Jan.2016 | www.siluj.com
e
8
9
¡¡¡ Caution !!!
Only use one type of connector / socket at a time!!
nglish
10
10