roublesHooting
This troubleshooting guide is meant to help solve simple problems.
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit operates properly,
do not carry out following steps.
Hoist (s) do not respond to the green RUN signal
Please check the cabling and the connections
The corresponding switch is set in the "0" position
The main circuit breaker is OFF
The red Emergency button is pressed
Too much resistance on one of the connectors
Controller does not respond
Please ckeck the powercable and the connecttions
All 3 red LED (L1, L2, L3) must be ON, otherwise one
of the phases is not present. DO NOT HOIST.
The main circuit breaker is switched OFF
control circuit breaker (4) is switched OFF
The red Emergency button is pressed
The surrounding temperature is too high/too low
Manual de usuario / User Manual | FR-419 Chainhoist controller | Rev. Jan.2016 | www.siluj.com
e
nglish
16
H
pin
arting socket
8
Harting
Pin
16
Out
Motor 1
Motor 2
Pin
Phase
Pin
Phase
1
R - L1
5
R - L1
2
S - L2
6
S - L2
3
T - L3
7
T - L3
4
8
Solution
Connect everything propely and/or measure
Set the main circuit break to ON
Turn the emergency button clockwise to release
Measure the resistance (Ohm) of the connectors
Solution
Connect everything properly and/or measure
Plesae check all 3 phases powerin
Set the main circuit breaket to ON
Set the swich to ON
Turn the emergency button clockwise to release
Place the chainhoist controller in a cooler/warmer plase