Basement Sentry STBB100 Manual De Instrucciones página 10

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS
15. LED Indicator Lights
Red light on and alarm sounds:
Battery backup pump is working
Red light slow flash and alarm sounds:
Pump wire connection problems or pump failure
Yellow light on:
Battery is recharging
Yellow light slow flash and alarm sounds:
Power off or power adapter failure
Yellow light quick flash and alarm sounds:
Battery is disconnected or DC fuse broken
Green light on:
The system is normal
OPERATION
NOTE: Sump basin must be filled with water before
operation. Running the pump dry will cause
damage and void the warranty.
1. Verify 115V pump operation by filling the basin
with enough water to raise the float on the
primary sump pump. Pump should start and
remove water.
Unplug the 115V from the power source.
2. Test DC pump operation by refilling the sump
basin with water until the DC pump float moves
to the top of the float rod.
The DC pump should start and pump water out
of the sump basin. If pump does not operate,
check all wire connections.
10
© 2020. All rights reserved.
15
Yellow
Red light on and alarm sounds:
Battery backup pump working
Red light slow flash and alarm sounds:
Pump wire connection problems or pump failed
Yellow light on:
Battery recharging
Yellow light slow flash and alarm sounds:
Power off or power adapter failed
Yellow light quick flash and alarm sounds:
Battery disconnected or DC fuse broken
Green light on:
System is normal
Green
1
2
Red
SW1401 A
RESET

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido