INSTALLATION INSTRUCTIONS
6. Wrap the DC pump discharge thread with Teflon
tape and attach a 1-1/4-in. FPT 90° elbow to the
discharge.
7. Wrap the thread of a 1-1/4-in. to 1-1/2-in
adapter (not included) with Teflon tape and
attach the adapter to the 90° elbow.
8. Install a "Y" pipe between the backup pump
discharge pipe and the primary pump discharge
6
7
8
Discharge
Discharge
7